| Denitrification Columns | | manual | buy or view price | | | Plastic polyethylene denitrification systems for marine or freshwater applications, the equipment is designed for clean water applications such as nitrate reduction in marine public aquaria | | | | | |  |  |  |  | column diameters = 400mm column heights = 2000mm area dims = 950mm x 1500mm bed depth =1250mm DFM media = 200kg Magphlow media = 360kg Product code =
Water flow (max) = 4 cubm/hr Max volume of aquarium = 200 cubm 5% water exchange per week Maximum biomass of fish = 500 kg | column diameters = 500 column heights = 2300 area dims = 1000 x 1400mm bed depth = 1500mm DFM media = 360kg Magphlow media = 626 kg Product code =
Water flow (max) = 6 cubm/hr Max volume of aquarium = 400 cubm 5% water exchange per week Maximum biomass of fish = 1000 kg | column diameters = 630 column heights = 2300 area dims = 1100 x 1650 mm bed depth = 1500mm DFM media = 550 kg Magphlow media = 900 kg Product code =
Water flow (max) = 10 cubm/hr Max volume of aquarium = 600 cubm 5% water exchange per week Maximum biomass of fish = 1500 kg | column diameters = 750 column heights = 2905 area dims = 1200 x 1800mm bed depth = 2000 mm DFM media = 1000 kg Magphlow media = 1800 kg Product code =
Water flow (max) = 20 cubm/hr Max volume of aquarium = 1000 cubm 5% water exchange per week Maximum biomass of fish = 2500 kg |
Sizing of the systems
The Denitrification process is very temperature dependent and works best above a minimum temperature of 16 deg C and up to temperatures as high as 40 deg C in marine systems. The process will also work in freshwater, but most of our data relates to marine aquaculture and public aquaria.
The maximum aquarium water volume relating to the column size is presented above. Please note that the size is only a recommendation, in different parts of the world and with different systems, stocking density, feed type, water temperature, water exchanges, species of fish or aquatic animal will reflect on the amount of ammonium produced, the degree of nitrification and the rate of nitrate increase. The above sizes should therefore only be considered as a recommendation.
|